OWNER’S MANUALJ-400™ S e r i e s J - 460 J - 465 J - 470 J - 4802530-442U Rev. A
Page 5J-400 Series9. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.Maintain water chemistry in accordance with manufacturer’s • instructions.Proper che
Page 6J-400 Series3.1 Entrapment RiskThe Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stu
Page 7J-400 Series3. ! DANGER: RISK OF SEVERE INJURY OR DROWNING! Body entrapment: May occur when part of the torso becomes entrapped, inserted or su
Page 8J-400 Series3.3 Important CSA safety instructions (Canada only)When using this electrical equipment, basic safety precautions should always be
Page 9J-400 SeriesWARNING: consult
Page 10J-400 Series4.2 Indoor LocationFor indoor installations many factors need to be considered before installing a spa indoors.Proper Foundation:
Page 11J-400 Series5.0 General Electrical Safety InstructionsYour new Jacuzzi® spa is equipped with the J-1000™ system. It contains the most advance
Page 12J-400 SeriesAll wiring must be copper to ensure proper connections. • Do not use aluminum wire.When using wire larger than #6 (10 mm²), add a
Page 13J-400 SeriesFigure A Equipment Area1042 2FlowNote: Pump Locations Vary by Model566987631111. Control Box2. Power Supply Entrance(s)3. Jet Pu
Page 14J-400 SeriesBLKREDREDREDBLKBLK12Figure-CTB1to Circuit BoardPower InGreenTB312BLUEBLUEBROWNBROWNFigure-DTB1to Circuit BoardPower InGreenTB3All N
ADDENDUMJacuzzi J-400 Series Owners Manual, #2530-442UYour new hot tub includes one of two stereo remote styles. Both remotes function 100% identical
Page 15J-400 SeriesExport J-460/J-465/J-470/J-480 Models (50Hz)Voltage: 230 VAC 230 VAC 230 VACMax. Current Draw: 16A 21A 29AFrequency: 50 Hz 50 Hz 50
Page 16J-400 Series• ! WARNING: TO DECREASE RISK OF INFECTION OR DISEASE. Fill hot tub with clean tap water from garden hose, to reduce risk of cont
Page 17J-400 Series7. Set Spa To Heat To warm spa water to a comfortable temperature, follow these steps:• The LCD display on the control panel dis
Page 18J-400 Series1. Add 2.5 ounces of sodium dichlor for every 100 gallons of water. Refer to the table below for approximate water ll volume by m
Page 19J-400 SeriesCAUTION: TO DECREASE BUILD UP ON COMPONENTS AND MINIMIZE ACRYLIC DAMAGE. Never ll with water from a water softener. If your water
Page 20J-400 Series9.0 Control Functions9.1 Control PanelA. Select Button: Filter cycle programming features. Pressing the select button also allo
Page 21J-400 Series9.2 LCD Display = Lock: Indicates panel, set temperature, or lter cycle programming is locked. = Heat: Indicates heater is on.
Page 22J-400 Series9.3 J-480 Spa Features12345910117345121385544376666141519181624322252121 2121171717202023Control Panel1. Waterfall Control Valve2.
Page 23J-400 Series9.4 J-470 Spa FeaturesControl Panel1. Waterfall Control Valve2. Air Control Valves (4 ea.) Introduce 3. Air to Specied Jet Groups
Page 24J-400 SeriesControl Panel1. Waterfall Control Valve2. Air Control Valves (3 ea.) Introduce 3. Air to Specied Jet Groups (Page 34)Optional Audi
Attention New Spa Owner!Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa
Page 25J-400 SeriesControl Panel1. Waterfall Control Valve2. Air Control Valves (4 ea.) Introduce 3. Air to Specied Jet Groups (Page 36)Optional Audi
Page 26J-400 Series10.0 Operating InstructionsYour Jacuzzi® spa has a touch-sensitive control panel, massage selectors, and air control knobs located
Page 27J-400 Series10.6 Light Mode ButtonThis button offers 4 light modes for your enjoyment. Press this button to select your favorite lighting eff
Page 28J-400 Series10.10 WaterColour™ Waterfall ControlTurn waterfall control valve (pages 29-36) counterclockwise to increase waterfall output. Tur
Page 29J-400 Series1a1a1b2b2b2a2a2a133555244Massage Selectors (1-2)• Massageselector1divertspump2outputbetweenjetsgroups1a-1b.• Massagese
Page 30J-400 Series11222234444431234Air Controls Operation• Rotate air controls 1-4 to add air to designated jet groups.• Center footwell IX Jet dra
Page 31J-400 Series1a1b2b2b2a2a133555244Massage Selectors (1-2)• Massageselector1divertspump2outputbetweenjetsgroups1a-1b.• Massageselect
Page 32J-400 Series1234431231141Air Controls Operation• Rotate air controls 1-4 to add air to designated jet groups.• Center footwell IX Jet draws a
Page 33J-400 Series1a1b1b1b4444412332Massage Selectors (1)• Massageselector1divertspump1outputbetweenjetsgroups1a-1b.Massage Selector (2)•
Page 34J-400 Series11222 22333132Air Controls Operation• Rotate air controls 1-3 to add air to designated jet groups.10.18 J-465 Air Controls Diagra
Table of Contents1.0 Important Spa Owner Information ... 12.0 FCC Notice ...
Page 35J-400 Series1a1bLK1441a44433 22Massage Selector (1)• Massageselector1divertspump1outputbetweenjetsgroups1a-1b.Massage Selector (2)•
Page 36J-400 SeriesLK4433533112224Air Controls Operation• Rotate air controls 1-4 to add air to designated jet groups.• Center footwell IX Jet (5) d
Page 37J-400 Series11.0 Heating ModesThe control system in your spa activates a programmable “standard” or “economy” mode which effects when the heat
Page 38J-400 Series12.0 Programming Instructions12.1 Programming Filter/Circulation Pump Run TimeThe Sentry control system allows you to easily adju
Page 39J-400 SeriesWhen in a Summer Logic condition is active (see note below), the lter/circulation pump will turn on for all programmed lter cycle
Page 40J-400 SeriesWhen a programmed lter/heating cycle activates, the LCD screen displays the following message:1*At any time, you may check the pro
Page 41J-400 Series12.5 Locking Filter CyclesYou may keep all lter cycle programs from being inadvertently altered by electronically “locking” them.
Page 42J-400 SeriesProgramming Instructions1. Press the CYCLE button 2 times. The main display reads “FIL” indicating the “Change Filter” display pr
Page 43J-400 Series13.0 Spa MaintenanceProper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jac
Page 44J-400 SeriesTo ensure optimum performance, the 24-hour ProClear™ II skimming lter cartridge (A) must be cleaned every three months and replac
11.0 Heating Modes ... 3711.1 Standard Mode (Factory Default) ..
Page 45J-400 Series6. Clean the ProClear lter cartridges with a garden hose and high pressure nozzle. Rinse debris from the lter pleats beginning a
Page 46J-400 Series5. Pull the larger (rear) body outward as shown to open drain.6. After the spa drains, perform steps 2-5 in reverse order to clos
Page 47J-400 Seriesagainst deterioration caused by UV rays from the sun. Never allow anyone to stand or sit on the cover, and avoid dragging it across
Page 48J-400 SeriesConsult your Jacuzzi dealer if you have any questions regarding winter use or winterizing.13.8 Restarting Your Spa in Cold Weather
Page 49J-400 Series14.0 Water Quality MaintenanceTo decrease the risk of contracting a waterborne illness (e.g. an infection, bacteria or virus) and/
Page 50J-400 SeriesWhen adding spa shock (chlorine or non-chlorine) or pH balancing chemicals activate the jets pump(s) and leave the spa cover open f
Page 51J-400 Series15.0 Troubleshooting - Display MessagesThere are a number of unique functions designed into your Jacuzzi spa to protect it from da
Page 52J-400 SeriesFREEZE PROTECTIONA potential freeze condition has been detected. No action is required. Jets pump(s) operate until the spa is out o
Page 53J-400 Series16.0 Troubleshooting - ProceduresIn the unlikely event your spa is not working the way you believe it should, please rst review a
Page 54J-400 SeriesPOOR JET ACTION (see page 29-36)1. Make certain the jets pump is turned on.2. Check position of massage selectors.3. Open air c
Page 1J-400 Series1.0 Important Spa Owner InformationYour Jacuzzi® spa is constructed to the highest standards and is capable of providing many years
Page 55J-400 Series17.0 North American 60 Hz J-460/J-465/J-470/J-480 Wiring DiagramK13J8 J6 J712VAC Output Power to LightingController.TransformerT1
Page 56J-400 Series18.0 Export 50 Hz J-460/J-465/J-470/J-480 Wiring DiagramK13J8 J6 J712VAC Output Power to LightingController.TransformerT1K1 K2 K3
Page 57J-400 SeriesRed (L2)PigtailNeutral BusGroundTB2TB1Black (L1)GreenMainServicePanelwithGFCI2-Pole GFCIBreakerGround/Bonding Lug**2-Pole Circuit B
Page 58J-400 Series20.0 Optional Jacuzzi J-1000 Audio System™ Stereo System Features20.1 Sound System Controls12173987546101113151216141. Power On/
Page 59J-400 Series20.2 Sound System Operation1. Power On and Off Press power button (1) once to turn on stereo system. Press a second time to tur
Page 60J-400 Series8. Adjusting Fader Level Press EQ button (5) repeatedly until display reads “FADER.” Press VOL Up/Down button (3) to choose desi
Page 61J-400 Series12. Open/Close Front Panel Press rmly on the release button (15), then open front panel (16) by gently lifting upward on bottom
Page 62J-400 Series5. Accessing Preset Stations Press and hold ENT/SH button (9) until display reads “SHIFT”. Repeatedly press TUN up or down butto
Page 63J-400 SeriesPress a second time to deactivate or press RDM button to cancel RPT function.4. Searching File or Folder in MP3/WMA CDTo Search F
Page 64J-400 Series2. Copying Music Files from USB to NAND (internal memory) In USB mode, press and hold SEL button (5) for about 2 seconds until
Page 2J-400 Series3.0 Important Safety Instructions for all Spa OwnersREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY!This spa was manufactured to meet th
Page 65J-400 Series20.6 J-1000™ Audio System iPod Operation1. Play iPod Open front panel (16) and plug a iPod into the iPod Docking Station (12) a
Page 66J-400 Series20.7 Docking your iPod Music Player1. Docking Your iPod The Docking Station for iPod is compatible with all dockable Apple iPod
Page 67J-400 Series20.8 Generic MP3 Player Operation1. Connecting Your MP3 PlayerA. The Audio unit is equipped with an auxiliary audio input jack,
Page 68J-400 Series2. Fogged CDs and Lens This condition may occur when it’s cold. Wipe fogged CDs with a soft cloth. Fogged optical components in
Page 69J-400 Series20.11 Standard Wireless Remote Control(Included With Optional J-1000 Sound System)• Usable range 15' (5m)• Never leave the
Page 70J-400 SeriesButton Operation Button OperationAutoAuto Button: Scans through preset radio stations.4Station 4 Preset Button: Has no CD/Radio fun
Page 71J-400 Series20.12 Wireless Remote Battery Replacement Procedure1. Start by removing the rubber cover to the remote (Figure A).2. Turn the re
Page 72J-400 SeriesSerial Number: ___________________________Model Name: ___________________________Dealer Name: __________________________
Page 3J-400 Serieson the grounding lug, inside the equipment compartment on the equipment box. A grounding wire connector is provided on this unit to
Page 4J-400 Series6. ! WARNING: RISK OF SEVERE INJURY OR DEATH! Since excessive water temperatures have a high potential for causing • fetal damage du
Comments to this Manuals