A10.0 2004 ProTech LED Circuit Board Wiring Diagram (US/Canada 60Hz)
J-335, J-345 US/Canada 60Hz Models
Circuit Board Type: ProTech LED, 6600-088.
TRANSFORMER
SPA
LIGHT
O
3
optional CD Ozone
Circ.
Pump
N
L
N
L
N
N
N
N L
L1
L2
N L
N L
L
L
L
L
PUMP
1
PUMP
2
LO
HI
HI
GRN
US / Canada 60 Hz Power Connections
240 VAC 60 Hz, 1-Phase;
USE COPPER CONDUCT
ORS ONLY, WIRE SIZE MUST
BE
APPROPRIA
TE PER NEC
AND/OR LOCAL
CODES
*
This device complies with Part
15 of the FCC rules. Operation is
subject to the following two
conditions:
1. This device may not cause
harmful interference.
2. This device must accept any
inteference received including
interference that may cause
undesired operation.
STEREO
*
(optional)
20A, 250 V, SC-20
Temp. Sensor
HI-Limit/Freeze Sensor
Flow Switch
Heater
5.5 kW
JP1
4
2
3
1
6 5
8 7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Logic Jumper Settings for all Domestic 60 Hz Models:
JP1 1-2 ON = 30
A
Logic (Overrides 60A
Logic)
JP1 1-2 OFF = 50
A
Logic
JP1 5-6 ON = 60
A
Logic (J-345 w/3.54 Chip Only)
JP1 5-6 OFF = 30 or 50A
Logic (3.54 Chip Only)
JP1 7-8 ON = C
T
emperature Display
JP1 7-8 OFF = F
Temperature Display