Jacuzzi LCD Series User Manual

Browse online or download User Manual for CD players Jacuzzi LCD Series. Jacuzzi LCD Series User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - LCD Series Owner’s Manual

ProTechTMLCD Series Owner’s Manual

Page 2

4.0 Choosing A LocationIMPORTANT: Because of the combined weight of the spa, water andusers, it is extremely important that the base upon which the s

Page 3 - Table of Contents

US/Canada J-350/J-360/J-370 Models (60Hz)240V/50A*240V/60A** 240V/30A***Voltage: 240 VAC 240 VAC 240 VACNumber of Wires: 3 3 3Frequency: 60Hz 60Hz 60H

Page 4

Export J-380 Models (50Hz)230V/40A* 230V/35A**Voltage: 230 VAC 230 VACNumber of Wires 3 3Frequency: 50Hz 50HzCurrent Draw: 32A 26ACircuit Breaker: 40A

Page 5 - 2.0 FCC Notice

Page 96.0 Electrical Wiring InstructionsIMPORTANTNOTICE: The electrical wiring of this spa must meetthe requirements of the National Electrical Code

Page 6

Page 10BLUEBLUEBROWNBROWN12US/Canada J-350 / J-360 / J-370 / J-380 Models: 240 VAC, 3-Wire Connection (60Hz)Figure-DTB1All Export J-350 / J-360 / J-37

Page 7

7.0 Start-Up InstructionsCongratulations! You are now all set to get your new spa ready to use. Simplyfollow this step-by-step procedure and, before

Page 8 - 3.3 CAUTIONS

7. 5 Add Start-Up ChemicalsAdd the spa water chemicals as recommended by your Jacuzzi PremiumDealer. Refer to section 13.0 (Page 36) for general guid

Page 9

8.2 LCD DisplayA. Lock Symbol indicates panel, set temperature, or filter cycle programming is locked.B. Heat Symbol: indicates heater is on (Sec. 9.1

Page 10 - 4.0 Choosing A Location

Page 141. Control Panel2. Air Controls3. Filter/Skimmer Cover4. Diverter Valve #25. Maxx PowerPro Jets6. PowerPro Jets/Mini-PowerPro Jets7. Diver

Page 11 - 5.0 Power Requirements

Page 159.0 Operating InstructionsYour Jacuzzi Premium spa has a touch-sensitive control panel, diverter valves,and air control knobs located on the t

Page 13

then repeatedly press the sensor pad to turn the light off or to select one of6 constant colors illustrated below.You must press the LIGHT sensor pad

Page 14 - 3. Grounding Terminal

customize the massage and performance by diverting waterbetween various jet systems. Simply turn diverter to positionA (Combo), B, or C to divert wat

Page 15 - 7.0 Start-Up Instructions

the latch tabs together at the top of each speaker enclosure to unlatch it’s “pop-up” mechanism. To retract each speaker before covering spa, gentlyp

Page 16 - 8.0 Control Functions

D. Adjust TreblePress blue SEL button two times toselect treble mode. Then press blueVOL or VOL button to adjust treblerange from -7 to +7.E.

Page 17 - 8.2 LCD Display

Page 20H. Bass BoostPress grey LOUD button to increase the bass output. LOUD appears on the display. I. Set ClockPress and hold grey DISP button for

Page 18 - 8.3 Spa Features And Controls

B. Select a Radio Station1. Slow Scan:Press blue + button or - button for less than one second to advance radio frequency up or down one step. 2. Q

Page 19 - 9.0 Operating Instructions

Page 22D. Recall a Station Preset1. Press grey BAND button to selectdesired radio band, if necessary.2. Press green PRESET button to recall station p

Page 20 - 9.5 Activate Pump 2/Pump 3

Optional Stereo Receiver - CD Player OperationA. Insert and Eject CD1. Press orange OPENbutton on front flip-over panel. Gently push a CD into slot

Page 21

E. Shuffle Play All TracksPress green SHF button to play all tracks on CD in random order one time. Press again to stop shuffle play.F. Scan (Preview

Page 22 - SEL/SEL/

Stereo Receiver SpecificationsOptional Stereo Receiver SpecificationsCD PlayerSignal/noise ratio . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 23

Table of Contents1.0 Important Spa Owner Information ...12.0 FCC Notice...

Page 24 - Optional Stereo Receiver

10.0 Automatic Filtration CyclesYour Jacuzzi Premium controls have been designed to provide maximumconvenience, as well as economy of operation. By

Page 25 - 5 SCN 6

Page 27Summer Logic: In warm weather, the water temperature in the spa mayexceed the set temperature. This condition may occur due to heat trans-feren

Page 26

Page 2811.0 Programming Instructions11 .1 Adjusting Time of DayThe control system remembers the time of day even in the event of a prolonged power ou

Page 27 - Insert CD Label Side Up

Page 29large four-digit display. Press WARMER ( + ) or COOLER ( - ) to adjustduration in increments of 15 minutes.4. Press DISPLAY to make the filte

Page 28

11 .4 Locking Filter CyclesYou may keep the filter cycle programs from being inadvertentlyaltered by electronically “locking” them. To accomplish thi

Page 29

the information, supplies, and accessory products you will need to accomplishthis.12.1 Cleaning The FiltersYour Jacuzzi Premium spa is equipped with

Page 30

Periodically, both filter cartridges will need a more thorough cleaning toremove imbedded oils and minerals. For this, we suggest cleaning as illus-tr

Page 31

CAUTION: There are certain precautions to keep in mind whendraining your spa. If it is extremely cold, and the spa is outdoors,freezing could occur in

Page 32 - 11.0 Programming Instructions

CAUTION: Never attempt to remove the pillows by pulling on them! Thepillows utilize a bolt-on design that prohibits removal without tools. To remo

Page 33

the spa has not been interrupted. In extreme, bitter cold weather less than -20 °F (-29 °C), reset the filter cycles for 24-hour operation to protect

Page 34 - 12 .0 Spa Maintenance

10.0 Automatic Filtration Cycles ...2610.1 Standard Filtration Mode ...

Page 35 - 12.1 Cleaning The Filters

13 .0 Water Quality MaintenanceMaintaining the quality of the water within specified limits will serve toenhance your enjoyment and prolong the life

Page 36 - 12.2 Draining and Refilling

Page 3713.3 Optional CD Ozone Water Maintenance SystemIf you have elected to have your spa equipped with the optional JacuzziPremium CD Ozone water p

Page 37 - 12.4 Pillow Care

If the spa water is more than 20 °F (-7 °C) cooler than the temperature setpoint, the low speed pump #1 and heater will automatically activate toprovi

Page 38 - 12.7 Winterizing

Communication between the control panel and/orremote control panel and circuit board is faulty.Contact your dealer or service center."WATCHDOG&qu

Page 39

2. If nothing appears on the screen:a. Check the household circuit breaker.b. Contact you dealer or authorized service center.PUMP DOES Depress "

Page 40 - 0 Water Quality Maintenance

Page 41footwell suction covers (Page 14).WATER IS TOO HOT. 1. Reduce thermostat setting.2. Reduce filtration cycle length. Even with heateroff, water

Page 41

Page 4216.0 Wiring DiagramJ-350/J-360/J-370 Models (USA/Canada 60Hz)SelectCycleModeDisplayyyPower Input: 240 VAC, 60A / 50A / 30A 1 PHASE, 60Hz; USE

Page 42

Page 4317.0 Wiring Diagram J-380 Models (USA/Canada 60Hz)SENSORSPower Input: 240 VAC, 60A / 50A / 40A1 PHASE, 60Hz; USE MIN. 6 AWG (10 mm2)COPPER CON

Page 43

Power Input: 230-240 VAC, 40A / 30A / 20A 1-Phase, 50Hz; USE MIN. 6 AWG (10 mm2)COPPER CONDUCTORS ONLYJ8J3TB7TB1TB1TB6TB5TR4TR2J6 J7OPTIONS SENSORS LC

Page 44

19.0 Wiring Diagram J-380 Models (Export 50Hz)Power Input: 230-240 VAC, 40A / 35A 1-Phase, 50Hz; USE MIN. 6 AWG (10 mm2) COPPER CONDUCTORS ONLYSENSOR

Page 45

1.0 Important Spa Owner InformationYour Jacuzzi® Premium spa is constructed to the highest standards and iscapable of providing many years of trouble

Page 46 - Transformer T1

TB1TB1Red (L2)PigtailNeutral BusGroundBlack (L1)GreenMainServicePanelwithGFCI2-Pole GFCIBreakerGround LugBonding LugBonding Lug2-Pole Circuit Breaker

Page 50 - US/Canada 60Hz Models Only

Jacuzzi® Premium14525 Monte Vista Ave. • Chino, CA 91710Website: http://www.jacuzzipremium.com6530-224, Rev. C © 2002 Jacuzzi Premium Printed in U.S.A

Page 51

3.0 IMPORTANT SAFETY INSTRUCTIONSWhen installing and using this electrical equipment, basic safety pre-cautions should always be followed, including:

Page 52

B. Since excessive water temperatures have a high potential for causing fetaldamage during the early months of pregnancy, pregnant or possibly preg-na

Page 53

C. WARNING: People with infectious diseases should not use a spa.D. WARNING: To avoid injury, exercise care when entering or exiting the spa.E. WARNIN

Page 54 - Jacuzzi® Premium

2. The Consumer Products Safety Commission has stated that the water temperature in a spa should not exceed 104 °F (40 °C). Immersion inwater in exces