OWNER’S MANUALJ-300™ Collection J - 315J - 325J - 335J - 345 J - 355 J - 365 J - 3752530-398W Rev. B
6J-300 3.1 Entrapment RiskThe Consumer Products Safety Commission/USA has reported that users of pools and spas have become entrapped (stuck) to drai
7J-3003. ! DANGER: RISK OF SEVERE INJURY OR DROWNING! Body entrapment: May occur when part of the torso becomes entrapped, inserted or sucked into a
8J-300 3.3 Important Additional CSA Safety Instructions (Canada Only)When using this electrical equipment, basic safety precautions should always be
9J-3004.0 Choosing A LocationIMPORTANT: Because of the combined weight of the spa, water and users, it is extremely important that the base upon whic
10J-300 4.1 Outdoor LocationIn selecting the ideal outdoor location for your spa, we suggest that you take into consideration:The proximity to changi
11J-300Proper Ventilation: an Engineer or authority competent enough to understand the necessary provis
12J-300 5.0 General Electrical Safety InstructionsYour new Jacuzzi spa is equipped with a “state-of-the-art” equipment system. It contains the most
13J-300240V/40A* 240V/50A** 240V/60A***Circuit Breaker (2-Pole): 40A 50A 60ANumber o
14J-300 230V/20A* 230V/30A** 230V/40A***Circuit Breaker: 20A 30A 40ANumber of Wires: 3 3 3Fr
15J-3007.0 Electrical Wiring InstructionsIMPORTANT NOTICE: The electrical wiring of this spa must meet the requirements of the National Electrical Co
Attention New Spa Owner!Congratulations on the purchase of your new Jacuzzi® spa! The following is a list of automated functions performed by your spa
16J-300 ANSI/NFPA 70. The disconnecting means must be readily accessible to the spa’s occupant but installed at least 5 feet (1.5m) from spa water. 7.
17J-300Figure B Control BoxTB13211. Terminal Block2. Bonding Lug3. Grounding TerminalGRNWHTWHTBLKBLKBLKRED123Figure-CTB1to Circuit BoardPower InGRN
18J-300 8.0 Spa Fill Up ProcedureFor best results, read each step in its entirety before proceeding with that step.1. Prepare The Spa For FillingCle
19J-3005. Add Start-Up ChemicalsAdd the spa water chemicals as recommended by your authorized Jacuzzi dealer. See Section 13.0 “Water Quality Mainten
20J-300 8. Place Cover On SpaKeeping the insulating cover in place anytime the spa is not in • use will reduce the time required for heating, thereby
21J-30010. Leave spa cover open during this step to allow excessive chemical vapors to exit spa, protecting pillows and plastic knobs from chemical
22J-300 WARNING: RISK OF PERSONAL INJURY.To decrease the risk of injury, entrapment or drowning, • never leave your hot tub unattended for any reason,
23J-3009.0 Control Functions9.1 Control PanelA. LED Display: Can display current water temperature (default display), water temperature set point,
24J-300 9.2 General Spa Features And Controls17811222225534613 1313131515145101010129617171716161616Control Panel1. Toggle Air Controls2. Filter/Skim
25J-30010.0 Operating InstructionsThe spa control system has automatic functions that operate upon start-up and normal operation to protect the syste
J-300Table of Contents1.0 Important Spa Owner Information...12.0 FCC Notice ...
26J-300 Pressing this button activates the waterfall, footwell light, lighted cup holders, and backlit pillows lights in uni
27J-30010.6 Selecting Desired Massage ActionAll models incorporate a massage selector valve that allows you to customize the massage and performance
28J-300 11.0 Automatic Filtration CyclesYour new spa includes a 24-hour circulation pump which lters the water continuously. The circulation pump dr
29J-300F0 5 minutes of ltration per day (one 5 minute “Blow-Out” cycle every 24 hours to purge all plumbing lines)F
30J-300 12.0 Spa MaintenanceProper and regular maintenance of your spa will help it retain its beauty and performance. Your authorized Jacuzzi dealer
31J-300An optional chemical feeder is available through your authorized Jacuzzi dealer that installs under the lter cap (#2472-673). Always remove t
32J-300 ELift unthreaded lter cartridge from skimmer well.FIf used, remove the chemical feeder as instructed prior to rinsing the lter cartridges. R
33J-300Periodically, the lter cartridge will need a more thorough cleaning to remove imbedded oils and minerals. For this, we suggest cleaning as ill
34J-300 12.3 Pillow CareRemove and clean the headrest pillows as needed with soapy water using a cloth or soft-bristle brush. Always remove the pillo
35J-300B. Additional Care and Maintenance Instructions:1. Debris can accumulate on the spa cover. Removal of snow or other debris will help to avoid
J-300 12.6 Maintaining The Synthetic Cabinet ... 3512.7 Winterizing ...
36J-300 CAUTION: TURN OFF POWER TO HOT TUB!1. Turn off power to the spa.2. Follow the directions on page 33 for draining the spa.3. Turn the massag
37J-300hot tub investment. For specic guidance on maintaining water quality, consult your Authorized Jacuzzi dealer who can recommend appropriate che
38J-300 WARNING:OR ENTRAPMENT!Never leave your hot tub unattended for any reason while the cover is open and access
39J-30014.3 Panel Displays ICEFreeze Protection - A potential freeze condition has been detected. No action is required. Jets Pump 1 and heater will
40J-300 Contact your authorized Jacuzzi dealer or qualied service technician.To correct condition:Remove the spa's cover and allow your spa to c
41J-3001. Jets may all be closed. Verify all jets are in the open “on” position (Sec. 10.5, page 26).2. Pump may not be properly primed. This can ha
42J-300 16.0 Circuit Board Diagrams Dedicated Power Models (60 Hz)This wiring diagram is us
43J-300 (60 Hz)This wiring diagram is used for all North American 120/240V 60 Hz convert
44J-300 This wiring diagram is used for all Export 230 VAC 50 Hz spa models.Optional S
45J-30016.4 Export J-315 and J-325 Models (50 Hz)This wiring diagram is used for all Export 230 VAC 50 Hz spa models.OzonatorOptionalO3TB1230 VAC, 3-
1J-3001.0 Important Spa Owner InformationYour Jacuzzi J-300 Collection spa is constructed to the highest standards and is capable of providing many y
46J-300 17.0 Optional Stereo Receiver Functions17.1 Stereo Receiver Control FunctionsSAT INFOAS-PSXBAS2ZONESUBWBANDSEARCHINT RPT RDMAUDIOENTERMODEMU
47J-300C. To navigate through the menus use the ( ) or ( ) buttons or press the MENU button repeatedly.D. To adjust the selected menu item, pres
48J-300 SAT INFOAS-PSXBAS2ZONESUBWBANDSEARCHINT RPT RDMAUDIOENTERMODEMULTI-ENVIRONMENTPLAYERTOP MENUAQ-CD-39876234110 51112 13 141815161719202122VOLUM
49J-300MIDDLE (Middle Level) : User has 5 seconds to use the Volume Up or Down button to adjust the desired Middle level range from -6 to +6.MID-CFQ
50J-300 SAT INFOAS-PSXBAS2ZONESUBWBANDSEARCHINT RPT RDMAUDIOENTERMODEMULTI-ENVIRONMENTPLAYERTOP MENUAQ-CD-39876234110 51112 13 141815161719202122FADER
51J-30014. While in seek mode the stereo unit will automatically select 6 strong stations and store t
52J-300 SAT INFOAS-PSXBAS2ZONESUBWBANDSEARCHINT RPT RDMAUDIOENTERMODEMULTI-ENVIRONMENTPLAYERTOP MENUAQ-CD-39876234110 51112 13 14181516171920212220.
53J-300 The system can only display the rst 8 letters of ID3 tags. If the recorded information is longer than 8 letters, text will scroll to the lef
54J-300 GeneralPower ...DC 11.5 -14.4VPre Output Voltage ...
55J-300A. 1. There are three different play methods as following:Press the M2 button more than 3 seconds during playing a
2J-300 3.0 Important Safety Instructions for all Spa OwnersREAD AND FOLLOW ALL INSTRUCTIONS CAREFULLY!This spa was manufactured to meet the standards
56J-300 2. File/Folder Repeat play :Press the M3 button more than 3 seconds during playing MP3/WMA • disc for “repeat play” for all les of the curre
57J-300ICON DESCRIPTIONFOLDER ICONFILE ICONTRACK ICONARTIST ICONALBUM ICON Before going through the check li
58J-300 ERROR Mechanism ErrorPress the eject button to correct the problem. If the error code does not disappear, consult your nearest service dealerD
59J-300B. Bonding the Remote and StereoIf your remote does not operate the stereo, you may need to bond them by pressing on of the following methods:
60J-300 17.7 Wireless Remote Battery Replacement Procedure1. Turn the remote unit over and locate the battery door (Figure A).2. Rotate the battery
3J-300unit and any metal equipment, metal enclosures of electrical equipment, metal water pipe, or conduit within 5 feet (1.5m) of the unit. Never per
4J-300 Persons suffering from obesity or a medical history of heart disease, • low or high blood pressure, circulatory system problems, diabetes, infe
5J-30010. CAUTION: TO DECREASE RISK OF PRODUCT DAMAGE.Maintain water chemistry in accordance with manufacturer’s • instructions.Proper chemical maint